<?xml version="1.0"?>
<Articles JournalTitle="Journal of Orthopedic and Spine Trauma">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Journal of Orthopedic and Spine Trauma</JournalTitle>
      <Issn>2538-2330</Issn>
      <Volume>7</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2021</Year>
        <Month>04</Month>
        <Day>20</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Intra-Pelvic Penetration of Broken Guide Wire during Fixation of Hip Fracture: Presentation of a Case and Review of Literature</title>
    <FirstPage>31</FirstPage>
    <LastPage>3</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Mehrdad</FirstName>
        <LastName>Sadighi</LastName>
        <affiliation locale="en_US">Department of Orthopedic Surgery, Shahid Beheshti University of Medical Sciences, Shohada Tajrish Hospital,  Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Meisam</FirstName>
        <LastName>Jafari Kafiabadi</LastName>
        <affiliation locale="en_US">Department of Orthopedic Surgery, Shahid Beheshti University of Medical Sciences, Shohada Tajrish Hospital,  Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Farsad</FirstName>
        <LastName>Biglari</LastName>
        <affiliation locale="en_US">Department of Orthopedic Surgery, Shahid Beheshti University of Medical Sciences, Shohada Tajrish Hospital,  Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mohammadreza</FirstName>
        <LastName>Chehrassan</LastName>
        <affiliation locale="en_US">Department of Orthopedic Surgery, Shahid Beheshti University of Medical Sciences, Shohada Tajrish Hospital,  Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Amin</FirstName>
        <LastName>Karami</LastName>
        <affiliation locale="en_US">Department of Orthopedic Surgery, Shahid Beheshti University of Medical Sciences, Shohada Tajrish Hospital,  Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Adel</FirstName>
        <LastName>Ebrahimpour</LastName>
        <affiliation locale="en_US">Department of Orthopedic Surgery, Shahid Beheshti University of Medical Sciences, Shohada Tajrish Hospital,  Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2020</Year>
        <Month>11</Month>
        <Day>22</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2021</Year>
        <Month>03</Month>
        <Day>29</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Background: The application of a cannulated device is a widely used fixation method for hip fractures. Although the breakage of the guide wire during this procedure is an uncommon complication, migration of the broken fragment might be catastrophic.
&#xD;

&#xA0;
&#xD;

Case Report: We presented a case of intertrochanteric fracture with breakage of the lag screw guide wire in the acetabulum during fixation with cephalomedullary nail. The broken fragment was located with computed tomography (CT) scan and removed through Stoppa approach.
&#xD;

&#xA0;
&#xD;

Conclusion: We found the Stoppa approach a safe and useful method for extracting the intra-pelvic broken guide wire.</abstract>
    <web_url>https://jost.tums.ac.ir/index.php/jost/article/view/243</web_url>
    <pdf_url>https://jost.tums.ac.ir/index.php/jost/article/download/243/215</pdf_url>
  </Article>
</Articles>
