Well-Performing Locking Plate Fixation with Calcar Screws Technique in Three-Part Proximal Humorous Fracture: Educational Corner
Abstract
Not abstract is available.
1. Frima H, Houwert RM, Beks RB, van Heijl M, van der V, Beeres FJP. Proximal humerus fractures; conservative or surgical treatment? Ned Tijdschr Geneeskd. 2019;163. [In Duth]. [PubMed: 30638000].
2. Gardner MJ, Weil Y, Barker JU, Kelly BT, Helfet DL, Lorich DG. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma. 2007;21(3): 185-91. doi: 10.1097/BOT.0b013e3180333094. [PubMed: 17473755].
3. Schliemann B, Wahnert D, Theisen C, Herbort M, Kosters C, Raschke MJ, et al. How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data. Injury. 2015;46(7):1207-14. doi: 10.1016/j.injury.2015.04.020. [PubMed: 25978864].
4. Kralinger F, Unger S, Wambacher M, Smekal V, Schmoelz W. The medial periosteal hinge, a key structure in fractures of the proximal humerus: A biomechanical cadaver study of its mechanical properties. J Bone Joint Surg Br. 2009;91(7):973-6. doi: 10.1302/0301-620X.91B7.21857. [PubMed: 19567866].
5. Yang P, Zhang Y, Liu J, Xiao J, Ma LM, Zhu CR. Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: A finite element analysis. Acta Orthop Traumatol Turc. 2015;49(2):203-9. doi: 10.3944/AOTT.2015.14.0204. [PubMed: 26012943].
6. Oppeboen S, Wikeroy AKB, Fuglesang HFS, Dolatowski FC, Randsborg PH. Calcar screws and adequate reduction reduced the risk of fixation failure in proximal humeral fractures treated with a locking plate: 190 patients followed for a mean of 3 years. J Orthop Surg Res. 2018;13(1):197. doi: 10.1186/s13018-018-0906-y. [PubMed: 30092807]. [PubMed Central: PMC6085712].
7. Wang Q, Sheng N, Rui B, Chen Y. The neck-shaft angle is the key factor for the positioning of calcar screw when treating proximal humeral fractures with a locking plate. Bone Joint J. 2020;102-B(12):1629-35. doi: 10.1302/0301-620X.102B12.BJJ-2020- 0070.R1. [PubMed: 33249912]. [PubMed Central: PMC7954146].
8. Zeng LQ, Zeng LL, Jiang YW, Wei HF, Zhang W, Chen YF. Influence of medial support screws on the maintenance of fracture reduction after locked plating of proximal humerus fractures. Chin Med J (Engl). 2018;131(15):1827-33. doi: 10.4103/0366- 6999.237396. [PubMed: 30058580]. [PubMed Central: PMC6071468].
9. Zarei M, Besharati S, Moharrami A, Ghaedi R. Acromion fracture and acromioclavicular joint dislocation: A case report. J Orthop Spine Trauma. 2020;4(4):74-6. doi: 10.18502/jost.v4i4.3099.
10. Zarei M, Moharrami A, Haghpanah B. Delay in anesthesia assessment time – A cause of postponement in orthopedic trauma surgery. Arch Trauma Res. 2020;9(4):176-80. doi: 10.4103/atr.atr_72_19
11. Jaeger M, Leung F, Li W. Deltopectoral Approach to the Proximal Humerus [Online]. [cited 2022 Dec 1]; Available from: URL: https://surgeryreference.aofoundation.org/orthopedic- trauma/adult-trauma/proximal- humerus/approach/deltopectoral-approach-to-the-proximal- humerus
12. Laux CJ, Grubhofer F, Werner CML, Simmen HP, Osterhoff G. Current concepts in locking plate fixation of proximal humerus fractures. J Orthop Surg Res. 2017;12(1):137. doi: 10.1186/s13018-017-0639-3. [PubMed: 28946902]. [PubMed Central: PMC5613450].
13. Osterhoff G, Ossendorf C, Wanner GA, Simmen HP, Werner CM. The calcar screw in angular stable plate fixation of proximal humeral fractures--a case study. J Orthop Surg Res. 2011;6:50. doi: 10.1186/1749-799X-6-50. [PubMed: 21943090]. [PubMed Central: PMC3189144].
14. Hajivandi S, Dachek A, Salimi A, Mamaghani HJ, Mirghaderi SP, Dehghani J, et al. Comparison of the separate and combined effects of physiotherapy treatment and corticosteroid injection on the range of motion and pain in nontraumatic rotator cuff tear: A randomized controlled trial. Adv Orthop. 2021;2021:6789453. doi: 10.1155/2021/6789453. [PubMed:
34733561]. [PubMed Central: PMC8560293].
15. Walsh S, Reindl R, Harvey E, Berry G, Beckman L, Steffen T. Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model. Clin Biomech (Bristol, Avon). 2006;21(10):1027-31. doi: 10.1016/j.clinbiomech.2006.06.005. [PubMed: 16919375].
16. Seebeck J, Goldhahn J, Stadele H, Messmer P, Morlock MM, Schneider E. Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. J Orthop Res. 2004;22(6):1237-42. doi: 10.1016/j.orthres.2004.04.001. [PubMed: 15475203].
17. Sharifpour S, Mirghaderi SP, Salimi M, Kalantar SH. Femoral retrograde nailing, an excellent choice for femoral shaft fracture with scarce complications: educational corner. J Orthop Spine Trauma. 2022;7(4):141-5. doi: 10.18502/jost.v7i4.8861.
18. Schumer RA, Muckley KL, Markert RJ, Prayson MJ, Heflin J, Konstantakos EK, et al. Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation. J Shoulder Elbow Surg. 2010;19(4):495-501. doi: 10.1016/j.jse.2009.11.003. [PubMed: 20189837].
19. Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ. Biomechanics of locked plates and screws. J Orthop Trauma. 2004;18(8):488-93. doi: 10.1097/00005131-200409000-00003. [PubMed: 15475843].
20. Beeres FJP, Hallensleben NDL, Rhemrev SJ, Goslings JC, Oehme F, Meylaerts SAG, et al. Plate fixation of the proximal humerus: an international multicentre comparative study of postoperative complications. Arch Orthop Trauma Surg. 2017;137(12):1685-92. doi: 10.1007/s00402-017-2790-z. [PubMed: 28929389].
21. Agudelo J, Schurmann M, Stahel P, Helwig P, Morgan SJ, Zechel W, et al. Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma. 2007;21(10):676-81. doi: 10.1097/BOT.0b013e31815bb09d. [PubMed: 17986883].
22. Mehta S, Chin M, Sanville J, Namdari S, Hast MW. Calcar screw position in proximal humerus fracture fixation: Don't miss high! Injury. 2018;49(3):624-9. doi: 10.1016/j.injury.2018.02.007. [PubMed: 29452734]. [PubMed Central: PMC7413303].
2. Gardner MJ, Weil Y, Barker JU, Kelly BT, Helfet DL, Lorich DG. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma. 2007;21(3): 185-91. doi: 10.1097/BOT.0b013e3180333094. [PubMed: 17473755].
3. Schliemann B, Wahnert D, Theisen C, Herbort M, Kosters C, Raschke MJ, et al. How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data. Injury. 2015;46(7):1207-14. doi: 10.1016/j.injury.2015.04.020. [PubMed: 25978864].
4. Kralinger F, Unger S, Wambacher M, Smekal V, Schmoelz W. The medial periosteal hinge, a key structure in fractures of the proximal humerus: A biomechanical cadaver study of its mechanical properties. J Bone Joint Surg Br. 2009;91(7):973-6. doi: 10.1302/0301-620X.91B7.21857. [PubMed: 19567866].
5. Yang P, Zhang Y, Liu J, Xiao J, Ma LM, Zhu CR. Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: A finite element analysis. Acta Orthop Traumatol Turc. 2015;49(2):203-9. doi: 10.3944/AOTT.2015.14.0204. [PubMed: 26012943].
6. Oppeboen S, Wikeroy AKB, Fuglesang HFS, Dolatowski FC, Randsborg PH. Calcar screws and adequate reduction reduced the risk of fixation failure in proximal humeral fractures treated with a locking plate: 190 patients followed for a mean of 3 years. J Orthop Surg Res. 2018;13(1):197. doi: 10.1186/s13018-018-0906-y. [PubMed: 30092807]. [PubMed Central: PMC6085712].
7. Wang Q, Sheng N, Rui B, Chen Y. The neck-shaft angle is the key factor for the positioning of calcar screw when treating proximal humeral fractures with a locking plate. Bone Joint J. 2020;102-B(12):1629-35. doi: 10.1302/0301-620X.102B12.BJJ-2020- 0070.R1. [PubMed: 33249912]. [PubMed Central: PMC7954146].
8. Zeng LQ, Zeng LL, Jiang YW, Wei HF, Zhang W, Chen YF. Influence of medial support screws on the maintenance of fracture reduction after locked plating of proximal humerus fractures. Chin Med J (Engl). 2018;131(15):1827-33. doi: 10.4103/0366- 6999.237396. [PubMed: 30058580]. [PubMed Central: PMC6071468].
9. Zarei M, Besharati S, Moharrami A, Ghaedi R. Acromion fracture and acromioclavicular joint dislocation: A case report. J Orthop Spine Trauma. 2020;4(4):74-6. doi: 10.18502/jost.v4i4.3099.
10. Zarei M, Moharrami A, Haghpanah B. Delay in anesthesia assessment time – A cause of postponement in orthopedic trauma surgery. Arch Trauma Res. 2020;9(4):176-80. doi: 10.4103/atr.atr_72_19
11. Jaeger M, Leung F, Li W. Deltopectoral Approach to the Proximal Humerus [Online]. [cited 2022 Dec 1]; Available from: URL: https://surgeryreference.aofoundation.org/orthopedic- trauma/adult-trauma/proximal- humerus/approach/deltopectoral-approach-to-the-proximal- humerus
12. Laux CJ, Grubhofer F, Werner CML, Simmen HP, Osterhoff G. Current concepts in locking plate fixation of proximal humerus fractures. J Orthop Surg Res. 2017;12(1):137. doi: 10.1186/s13018-017-0639-3. [PubMed: 28946902]. [PubMed Central: PMC5613450].
13. Osterhoff G, Ossendorf C, Wanner GA, Simmen HP, Werner CM. The calcar screw in angular stable plate fixation of proximal humeral fractures--a case study. J Orthop Surg Res. 2011;6:50. doi: 10.1186/1749-799X-6-50. [PubMed: 21943090]. [PubMed Central: PMC3189144].
14. Hajivandi S, Dachek A, Salimi A, Mamaghani HJ, Mirghaderi SP, Dehghani J, et al. Comparison of the separate and combined effects of physiotherapy treatment and corticosteroid injection on the range of motion and pain in nontraumatic rotator cuff tear: A randomized controlled trial. Adv Orthop. 2021;2021:6789453. doi: 10.1155/2021/6789453. [PubMed:
34733561]. [PubMed Central: PMC8560293].
15. Walsh S, Reindl R, Harvey E, Berry G, Beckman L, Steffen T. Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model. Clin Biomech (Bristol, Avon). 2006;21(10):1027-31. doi: 10.1016/j.clinbiomech.2006.06.005. [PubMed: 16919375].
16. Seebeck J, Goldhahn J, Stadele H, Messmer P, Morlock MM, Schneider E. Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. J Orthop Res. 2004;22(6):1237-42. doi: 10.1016/j.orthres.2004.04.001. [PubMed: 15475203].
17. Sharifpour S, Mirghaderi SP, Salimi M, Kalantar SH. Femoral retrograde nailing, an excellent choice for femoral shaft fracture with scarce complications: educational corner. J Orthop Spine Trauma. 2022;7(4):141-5. doi: 10.18502/jost.v7i4.8861.
18. Schumer RA, Muckley KL, Markert RJ, Prayson MJ, Heflin J, Konstantakos EK, et al. Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation. J Shoulder Elbow Surg. 2010;19(4):495-501. doi: 10.1016/j.jse.2009.11.003. [PubMed: 20189837].
19. Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ. Biomechanics of locked plates and screws. J Orthop Trauma. 2004;18(8):488-93. doi: 10.1097/00005131-200409000-00003. [PubMed: 15475843].
20. Beeres FJP, Hallensleben NDL, Rhemrev SJ, Goslings JC, Oehme F, Meylaerts SAG, et al. Plate fixation of the proximal humerus: an international multicentre comparative study of postoperative complications. Arch Orthop Trauma Surg. 2017;137(12):1685-92. doi: 10.1007/s00402-017-2790-z. [PubMed: 28929389].
21. Agudelo J, Schurmann M, Stahel P, Helwig P, Morgan SJ, Zechel W, et al. Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma. 2007;21(10):676-81. doi: 10.1097/BOT.0b013e31815bb09d. [PubMed: 17986883].
22. Mehta S, Chin M, Sanville J, Namdari S, Hast MW. Calcar screw position in proximal humerus fracture fixation: Don't miss high! Injury. 2018;49(3):624-9. doi: 10.1016/j.injury.2018.02.007. [PubMed: 29452734]. [PubMed Central: PMC7413303].
Files | ||
Issue | Vol 8, No 4 (2022) | |
Section | Educational Corner | |
DOI | https://doi.org/10.18502/jost.v8i4.10456 | |
Keywords | ||
Bone Plates Bone Screws Humeral Head Proximal Humeral Fracture Shoulder Fractures |
Rights and permissions | |
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. |
How to Cite
1.
Mirghaderi SP, Sharifpour S, Rahmanipour E, Salimi M, Salehi M, Guity MR. Well-Performing Locking Plate Fixation with Calcar Screws Technique in Three-Part Proximal Humorous Fracture: Educational Corner. J Orthop Spine Trauma. 2022;8(4):138-141.